Product details: Model ZLT-GTR:
The device is designed to carry out fire hazard testing on electrotechnical products in accordance with the provisions of International standards.
The control unit is supplied with all the controls and metering necessary to accurately set the temperature of the glow wire. The wire current is continuously variable by means of the panel-mounted controller and is monitored by the built-in ammeter. A digital temperature indicator is fitted which, in conjunction with the thermocouple supplied, accurately measures the glow wire temperature. The electrical circuit of the control unit is fully protected by fuses and a miniature circuit breaker and incorporates mains on/off switching and push button control of the output current. Self contained cabinet with large viewing window and dark colored interior.
The device is designed to carry out fire hazard testing on electrotechnical products in accordance with the provisions of International standards.
The control unit is supplied with all the controls and metering necessary to accurately set the temperature of the glow wire. The wire current is continuously variable by means of the panel-mounted controller and is monitored by the built-in ammeter. A digital temperature indicator is fitted which, in conjunction with the thermocouple supplied, accurately measures the glow wire temperature. The electrical circuit of the control unit is fully protected by fuses and a miniature circuit breaker and incorporates mains on/off switching and push button control of the output current. Self contained cabinet with large viewing window and dark colored interior.
| Glow Wire Element | Ni/Cr wire, diameter: |
|
| Temperature |
50ºC – 960ºC | |
| Current |
0 to |
|
| Thermocouple | Type K (Ni/Cr - Ni/Al) | |
| Thermocouple Size O/D | 0.5 mm | |
| Temperature Resolution | 1ºC | |
| Traverse Unit | Horizontal | |
| Force | 1 N±0.2N | |
| Maximum Travel | 14.5 cm | |
| Test Travel Limit | 7 mm | |
| Flame Height Indicator | 30 cm | |
| Input Power | 220 V 50 Hz |
|
| Volume Of Chamber | > |
|
| Outer Dimensions | W*D*H= |
|
| Conform to standard | IEC6 |
|
| Fitted to the base plate are a flame height scale, a level and adjustable feet | ||
| DIGITAL TEMPERATURE DISPLAY | ||
Includes:
A white Pine Test Board and five Sheets of Tissue Paper
Consumables:
White Pine Test
Board Tissue Paper
Glow Wire Loop
Thermocouple Type K
A white Pine Test Board and five Sheets of Tissue Paper
Consumables:
White Pine Test
Board Tissue Paper
Glow Wire Loop
Thermocouple Type K
Guangzhou Zhilitong Electromechanical Co., Ltd.

Tel:
Faq:
Add:
Email: