High Voltage Arc Ignition Tester Product details:Model ZLT-HVL This test method covers, in a preliminary fashion, the differentiation among similar materials with respect to their resistance to the action of a high-voltage, low-current arc close to the surface of insulation, intending to form a conducting path therein or in causing the material to become conducting due to the localized thermal and chemical decomposition and erosion,according to IEC61621, ASTMD495, UL746A Klausel 22.2. Standard-Outfit: 1 Bogenresistenz-Testkreis, um eine Hochspannung von bis zu 12,5 kV, einstellbare 1 Stromkontrollwiderstände mit R10, R20, R30, R40-Four-Widerständen bereitzustellen, liefern Lichtbogenströme von 10 mA, 20 mA, 30 mA und 40 mA, 1 Milliammeter, a-an A-AC-ACMMEMEMEL. 2,4mm±0,05mm diameter tungsten rod which is free from cradks,pits or rough spots,the free electrode length shall be a minimum of 20 mm,shall be ground and polished to produce and angle of 300±10 to the axis, 1 electrode fixture ,to provides a means of holding the electrodes and the test specimen at the proper angle for applying the arc to the tip surface of the test specimen,each electrode shall be adjusted so that it rests independently on the test specimen with a force of 0,5N±0,05N,they lie in the same vertical plane and are both inclined 350±10 from the horizontal, 1 gauge, to measure the 6.35mm±0.08mm of two space the tips, 1 test chamber,enclosure without venting,dimensions not smaller than 300mm×150mm×100mm, Power supply: 220V50Hz Andere Spannungen Anfrage.