+  86- 18011959092 / +86- 13802755618
Hic es: Home » Products » Flammability Tester and Other Plastics Tester » IEC 60332 Cable Flamma Tester

loading

IEC 60332 Insulated Cable Flame Tester

professionales sumus Propagationis Tester fabricatores flammae , 1 KW praemixta flammae experimentum Machina pro Singula cable Flamma Insulae Tester , secundum in IEC60332-1 et IEC60332-1-2.
  • Item NO.:ZLT-BS1
  • Order(MOQ): 1
  • Payment:T/T
  • Product Origin: China
  • Shipping Portus: Guangzhou
  • Ne tempus XX diebus
Availability:
Quantitas:
facebook sharing button
Twitter sharing button
linea participatio puga
wechat sharing button
sharingin button sharing
pinterest sharing button
whatsapp sharing button
kakao sharing button
snapchat button sharing
sharethis sharing button
  • ZLT-BS1

  • ZLTJC

  • ZLT-BS1



Flamma vexillum: IEC60695-112,1KW flammae nominalis praemixta
Tubus turibulum; IEC60695-112 figure A
Angulus ardenti

45°

Thermocouple

Type K (Ni/Cr - Ni/Al), 200° 1050 °

Thermocouple Location O / D *

0.5 mm
Temperature Resolution

1oC'

Vexillum aeris scandalum pondus: 10 ± 0 .05 g ante diam. Cu-ETP
Gas supplementum (non procídere)

propane, min.95% puritatis

Potentia potenti

220 V 50 Hz 3A vel 115 V 60HZ Libitum

Dimensiones interiores

W*D*H=300mm*450mm*1200mm



Product Overview


solutio Flamma Propagationis Tester ZLT-BS1 professionalis est ad dijudicandam flammae verticalis propagationem resistentiam unius verticalis electrica insulati conductores, ancoras et fibra optica ancoras. In linea cum IEC60332-1 et signis IEC60332-1-2 evolutae , haec probator notae flammae 1KW nominalis praemixtae flammae (per IEC60695-11-2 ) ad missiones duras ignis replicare. Pro fabrica credita, ZLT-BS1 offerimus cum MOQ de 1 unitate, solutione per T/T, naves e Guangzhou Port, et tempus plumbeum XX dierum . Late usus est in funiculo fabricationis, explorationis electricae, et obsequii regulatorii ut funes ad occursum globalis ignis salute requisita.



Flamma Propagationis Test pro uno Insulated cableFlamma Propagationis Test pro uno Insulated cable



Product Features


Fons normatum flamma

IEC60695-112 Flamma praemixta 1KW (per ) servat caloris output constantem tradit, eventus experimenti praestandi trans labs comparabiles sunt. Ustoris consilium (figuram A IEC60695-112 aequans) figuram et intensionem flammae uniformis praestat.


Precise Temperature Cras

Typus K thermocouplus (0.5mm O/D) praebet amplis temperaturas (200℃~1050℃) et 1℃ resolutionem , ut flammae temperamentum reale tempus habeat. Haec praecisio adiuvat ut subtiliores mutationes in fune flamma resistentia cognoscantur.


Robustus Test Chamber

Cubiculum internus 300mm×450mm×1200mm amplum spatium praebet ad exempla fune verticalis, dum angulus turibulum 45° (fixus) flammam mutuam facit cum fune in modo normato-critico pro iterabili eventu.


Compatibility versatile

Probator operatur cum singulis conductoribus insulatis, retinacula potentiae, et fibra optica, quae pluribus industriis (eg, electronicis, telecommunicationibus, automotivis) aptam facit.


Applicationem


ZLT-BS1 essentialis est pro societatibus quae in fune salutis et obsequii implicantur, inter quas:


Cables Manufacturers : probatio productorum perfectorum (exempli, PVC-insulatae rudentes, fibra optica) ut occurrant IEC60332-1 requisita ante forum launch.

Electrical Equipment Makers : Verificare flammam resistentiam funem adhibitis in adjumenta (eg, refrigeratoria, aeris conditioners) ad praecavenda pericula ignis.

Industry telecommunicationum : Tentatio funes fibrarum opticorum ut resistant propagandae flammae in notitiis centris vel officinae velit.

Examinatio Labs : Auditorum conductio tertia factio clientium in sectoribus aerospace, marinis, et industrialibus, ubi cable ignis salus critica est.


FAQ


Quis gas exigitur pro ZLT-BS1 et includitur?

A1: Probator propensionem requirit cum minima 95% puritate , sed gas non provisum est (ad rationes securitatis naviculas obtemperandas). Customers ex certificatis praebitoribus localiter proponere possunt.


Possuntne ZLT-BS1 experiri retinacula fibra optica?

A2: Ita. Probator ad singulas verticales electricas insulatas conductores, rudentes et fibra optica destinata , sicut in IEC60332-1 et IEC60332-1-2 designatur..


Quid istuc est regulae aeris scandalum?

A3: De 10±0.05g Cu-ETP truncus aeris adhibetur ad temperaturam flammam calibrandam (per IEC60695-112 ), ut flamma 1KW occurrat vexillum caloris output requisita ante probationem.


Q4: Estne potestas copia compatibilis cum regionibus 110V 60Hz (eg, America Septentrionalis)?

A4: Sic. Mensura vis copiae 220V 50Hz 3A est, at nos offerimus . 115V 60Hz configurationem pro regionum cum diversis systematibus electricis Quaeso te confirmare necessitates tuas cum ordinatione.



Priora: 
Next: 
Habemus turmas professionales venditionesque magnas victuarios, mercatum altum praesentiam, officia intercessantia praeclara.

ORIGINAL LINKS

PRODUCTS CATEGORY

Contact Us

Phone:+86- 18011959092
                ~!phoenix_var295!~
Tel:+86-20-8160059
         +86-20-81600135
Email: oxq@electricaltest.com .cn
               zlt@electricaltest.com .cn
Add:166-8 Longxi Medio Via, Liwan Districtus, Guangzhou, China
Aliquam Nuntius
Contact Us
Copyright © 2024 Guangzhou Zhilitong Electromechanical Co, Ltd. All rights reserved. | Sitemap | Privacy Policy | Supported by leadong.com