+86-18011959092 / +86-13802755618
You are here: Home » Products » Flammability Tester and Other Plastics Tester » IEC 60332 Insulated Cable Flame Tester

loading

IEC 60332 Insulated Cable Flame Tester

We are professional Flame propagation Tester manufacturers, 1 KW pre-mixed flame test Machine for Single Insulated cable Flame Chamber Tester,according in IEC60332-1 and IEC60332-1-2.
  • Item NO.:ZLT-BS1
  • Order(MOQ):1
  • Payment:T/T
  • Product Origin:China
  • Shipping Port:Guangzhou
  • Lead Time:20 days
Availability:
Quantity:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
kakao sharing button
snapchat sharing button
sharethis sharing button
  • ZLT-BS1

  • ZLTJC

  • ZLT-BS1



Flame standard: IEC60695-11-2,1KW nominal pre-mixed flame
Burner tube: IEC60695-11-2 figure A
Burning angle

45°

Thermocouple

Type K (Ni/Cr – Ni/Al),200°1050°

Thermocouple Size O/D

0.5 mm
Temperature Resolution

1oC

Standard copper block weight:10 ± 0 .05 g before drilling. Cu-ETP
Gas supple(do not procide)

propane,min.95% purity

Input power

220 V 50 Hz 3A or 115 V 60HZ  Optional

Inner dimensions

W*D*H=300mm*450mm*1200mm



Product Overview


The ZLT-BS1 Flame Propagation Tester is a professional solution for evaluating the vertical flame propagation resistance of single vertical electrical insulated conductors, cables, and optical fibre cables. Developed in line with IEC60332-1 and IEC60332-1-2 standards, this tester features a 1KW nominal pre-mixed flame (per IEC60695-11-2) to replicate harsh fire scenarios. As a trusted manufacturer, we offer the ZLT-BS1 with an MOQ of 1 unit, payment via T/T, shipping from Guangzhou Port, and a lead time of 20 days. It is widely used in cable manufacturing, electrical safety testing, and regulatory compliance to ensure cables meet global fire safety requirements.



Flame Propagation Test for a Single Insulated CableFlame Propagation Test for a Single Insulated Cable



Product Features


Standardized Flame Source

The 1KW pre-mixed flame (per IEC60695-11-2) delivers consistent heat output, ensuring test results are comparable across labs. The burner’s design (matching IEC60695-11-2 Figure A) guarantees uniform flame shape and intensity.


Precise Temperature Monitoring

The Type K thermocouple (0.5mm O/D) offers a wide temperature range (200℃~1050℃) and 1℃ resolution, enabling real-time tracking of flame temperature. This precision helps identify subtle changes in cable flame resistance.


Robust Test Chamber

The internal 300mm×450mm×1200mm chamber provides ample space for vertical cable samples, while the 45° burner angle (fixed) ensures flame interacts with the cable in a standardized way—critical for repeatable results.


Versatile Compatibility

The tester works with single insulated conductors, power cables, and optical fibre cables, making it suitable for multiple industries (e.g., electronics, telecommunications, automotive).


Application


The ZLT-BS1 is essential for organizations involved in cable safety and compliance, including:


Cable Manufacturers: Testing finished products (e.g., PVC-insulated cables, optical fibre cables) to ensure they meet IEC60332-1 requirements before market launch.

Electrical Equipment Makers: Verifying the flame resistance of cables used in appliances (e.g., refrigerators, air conditioners) to prevent fire hazards.

Telecommunications Industry: Testing optical fibre cables to ensure they resist flame propagation in data centers or outdoor installations.

Testing Labs: Conducting third-party audits for clients in aerospace, marine, and industrial sectors, where cable fire safety is critical.


FAQ


What gas is required for the ZLT-BS1, and is it included?

A1: The tester requires propane with a minimum 95% purity, but gas is not provided (to comply with shipping safety regulations). Customers can source propane locally from certified suppliers.


Can the ZLT-BS1 test optical fibre cables?

A2: Yes. The tester is designed for single vertical electrical insulated conductors, cables, and optical fibre cables—as specified in IEC60332-1 and IEC60332-1-2.


What is the purpose of the standard copper block?

A3: The 10±0.05g Cu-ETP copper block is used to calibrate the flame temperature (per IEC60695-11-2), ensuring the 1KW flame meets standard heat output requirements before testing.


Q4: Is the power supply compatible with 110V 60Hz regions (e.g., North America)?

A4: Yes. The standard power supply is 220V 50Hz 3A, but we offer an optional 115V 60Hz configuration for regions with different electrical systems. Please confirm your needs when ordering.



Previous: 
Next: 
We have a professional sales team, extensive suppliers, a deep market presence, and excellent one-stop services.

QUICK LINKS

PRODUCTS CATEGORY

CONTACT US

Phone:+86-18011959092
                +86-13802755618
Tel:+86-20-81600059
         +86-20-81600135
Email: oxq@electricaltest.com.cn
               zlt@electricaltest.com.cn
Add:166-8 Longxi Middle Road, Liwan District, Guangzhou, China
Leave a Message
Contact Us
​Copyright © 2024 Guangzhou Zhilitong Electromechanical Co., Ltd. All rights reserved. | Sitemap | Privacy Policy | Supported by leadong.com