IEC 60454-2 High Pressure-Sensitive Tape Flame Tester

We are professional Insulating Tape Flame Test Apparatus manufacturers, Pressure-sensitive adhesive tapes flame test apparatus,conform to IEC60454-2 clause 20 and figure 10, UL 510 clause 6.
  • Item NO.:ZLT-BS2
  • Order(MOQ):1
  • Payment:T/T
  • Product Origin:China
  • Shipping Port:Guangzhou
  • Lead Time:20 days
Availability:
Quantity:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
kakao sharing button
snapchat sharing button
sharethis sharing button
  • ZLT-BS2

  • ZLTJC

  • ZLT-BS2


Product Overview


As a professional manufacturer of insulating tape testing equipment, we present the ZLT-BS2 Pressure-Sensitive Adhesive Tapes Flame Test Apparatus—a precision instrument designed to evaluate the resistance to flame propagation of insulating tapes. Compliant with international standards IEC60454-2 Clause 20 (including Figure 10) and UL 510 Clause 6, this apparatus ensures accurate, repeatable test results for quality control and compliance verification. Originating from China, the product supports a minimum order quantity (MOQ) of 1 unit, with payment via T/T, shipping from Guangzhou Port, and a lead time of 20 days. It is widely trusted by tape manufacturers, electrical safety laboratories, and quality inspection institutions for its reliability and adherence to global safety norms.


ul 510 Insulating Tape Flame Test Apparatus

Technical Parameters




Parameter Category

Specification Details

Model

ZLT-BS2

Compliant Standards

IEC60454-2 Clause 20 (Figure 10/11), UL 510 Clause 6

Burner Configuration

Internal diameter: 9.5mm; Length above air inlets: 102mm; Angle: 20° from vertical (per IEC60454-2 Figure 11)

Thermocouple

Type K (Chromel-alumel); Temperature range: ≥816℃; Digital display function

Steel Mandrel

Diameter: 3.5mm; Length: 460mm; Tension load: 2kg±20g (attached to tape free end)

Protective Device

Three-sided metal enclosure; Dimensions: 305mm (W) × 355mm (D) × 610mm (H); Open top/front

Auxiliary Components

Flame height measurement scale; Winding jig (supports mandrel rotation for tape winding)

Power Supply

Standard: 220V 50Hz; Custom voltages available on request

MOQ & Lead Time

1 unit; 20 days



Insulating Tape Flame Test Apparatus


Product Features


High Compliance & Accuracy

The ZLT-BS2 strictly follows IEC60454-2 and UL 510 standards, ensuring test results are recognized globally. The Type K thermocouple with a digital display (≥816℃ range) provides real-time, precise temperature monitoring, while the flame height scale allows for visual verification of flame intensity.


Stable Test Conditions

A 2kg±20g tension mass attached to the tape ensures consistent stress during testing, and the winding jig enables smooth, uniform tape winding on the mandrel—eliminating human error in sample preparation. The burner’s fixed 20° angle (per IEC60454-2 Figure 11) guarantees repeatable flame application.


Safety & Durability

The three-sided metal enclosure (305mm×355mm×610mm) prevents flame spread and protects operators from heat radiation. All components (e.g., steel mandrel, burner) are made of high-temperature-resistant materials, ensuring long-term use in harsh testing environments.


Pressure Sensitive Adhesive Tapes Flame Test


Application


The ZLT-BS2 is ideal for scenarios requiring strict flame resistance testing of pressure-sensitive adhesive tapes, including:


Electrical Insulation Industry: Testing insulating tapes used in motors, transformers, and electrical enclosures to ensure compliance with safety standards.

Tape Manufacturers: Quality control during production to verify that tapes meet customer or regulatory flame propagation requirements.

Third-Party Testing Labs: Conducting independent compliance audits for clients in the electronics, automotive, and aerospace sectors.

Regulatory Bodies: Enforcing safety standards by verifying that tapes sold in the market adhere to IEC60454-2 and UL 510.


FAQ


Q1: Which standards does the ZLT-BS2 fully comply with?

A1: It meets IEC60454-2 Clause 20 (including the geometric requirements of Figure 10 for sample fixing and Figure 11 for burner angle) and UL 510 Clause 6—two of the most authoritative standards for insulating tape flame testing.


Q2: Can the power supply be customized for regions with 110V 60Hz?

A2: Yes. The standard power supply is 220V 50Hz, but we offer custom configurations (e.g., 110V 60Hz) to match regional electrical systems. Please specify your requirements when ordering.


Q3: How is the test specimen secured during testing?

A3: The apparatus includes a dedicated specimen holder that fixes the tape’s longitudinal axis vertically to the center of the protective enclosure (per IEC60454-2 Figure 10). This ensures the flame acts on the tape in a consistent, standardized manner.


Q4: What is the purpose of the steel mandrel and tension mass?

A4: The 3.5mm×460mm steel mandrel is used to wind the test tape, while the 2kg±20g mass applies constant tension. This simulates real-world stress on the tape and ensures flame propagation is tested under realistic conditions.




Previous: 
Next: 
We have a professional sales team, extensive suppliers, a deep market presence, and excellent one-stop services.

QUICK LINKS

PRODUCTS CATEGORY

CONTACT US

Phone:+86-18011959092
                +86-13802755618
Tel:+86-20-81600059
         +86-20-81600135
Email: oxq@electricaltest.com.cn
               zlt@electricaltest.com.cn
Add:166-8 Longxi Middle Road, Liwan District, Guangzhou, China
Leave a Message
Contact Us
​Copyright © 2024 Guangzhou Zhilitong Electromechanical Co., Ltd. All rights reserved. | Sitemap | Privacy Policy | Supported by leadong.com