In hac editione figure IX destructionem test apparatu, reponit senior figure XIX de maioris.
Test adtracto, ad hoc test est cognoscere quod Contactus Connectors et appliance exitus sufficient machinas vires.
ZLT Pulling Test Apparatus,to determine the mechanical strength of the connector, accordance with IEC60320-1:2021 figure 9 and clause 23.3 &23.6.3, a lateral pull force is applled in steps of 90 0±5 0 as shown in IEC 60320 figure 8a),b),C),d) and e) parallel with the plane containing the axes of the current-carrying pins/contacts and parallel with the engagement face of the Connector / plug iungo.