Product Overview


The ZLT-P12 Cylinder Test Tool Probe is a specialized entrapment testing device developed by ZLTJC to meet the rigorous safety standards of IEC 60601-2-52:2009 Figure 201.103b. It is primarily used to evaluate the entrapment risk of medical equipment— a critical safety check to prevent harm to patients,or users during device operation.

Constructed entirely from high-quality stainless steel, the ZLT-P12 offers exceptional durability and resistance to wear, ensuring consistent performance in high-frequency testing environments. A key technical specification is its precise weight control: the total weight of the tool is 3.34 kg±0.05 kg—a parameter strictly calibrated to replicate real-world entrapment scenarios as defined by the IEC standard.


The tool features a marked centre line for accurate alignment during tests, a surface roughness of 1.6 μm to minimize friction-related test errors, and a drilling hole for weight adjustment (allowing fine-tuning if specific testing requirements demand slight modifications). Manufactured in China, the ZLT-P12 has an MOQ of 1 unit, accepts payment via T/T or D/P, and has a lead time of 10 days, with shipments departing from Guangzhou port.


Ideal for medical device manufacturers, certification labs, and safety inspectors, the ZLT-P12 ensures that medical equipment (such as hospital beds, patient lifts, or diagnostic machines) complies with global entrapment safety regulations, reducing liability and protecting end-users.


Cylinder Test Tool


Technical Parameters




Parameter Category

Specification Details

Model Number

ZLT-P12

Brand

ZLTJC

Compliance Standard

IEC 60601-2-52:2009 Figure 201.103b

Core Application

Entrapment risk testing for medical equipment

Material

High-quality stainless steel

Total Weight

3.34 kg±0.05 kg

Surface Roughness

1.6 μm

Key Features

Marked centre line; drilling hole for weight adjustment

Critical Dimensions (mm)

318±1 mm, 50-0.90 mm, 43.022 mm

Product Origin

China

MOQ

1 unit

Payment Terms

T/T, D/P

Lead Time

10 days

Shipping Port

Guangzhou, China



Product Features


Medical-Grade Safety Compliance: Strictly adheres to IEC 60601-2-52:2009 Figure 201.103b—the global standard for medical device entrapment testing—ensuring results are accepted for CE, FDA, and other international certifications.

Precision Weight Calibration: Total weight of 3.34 kg±0.05 kg replicates real-world entrapment forces, eliminating test inaccuracies caused by weight deviations.

Low Friction Surface: Surface roughness of 1.6 μm reduces friction between the tool and tested equipment, ensuring the entrapment force measured is accurate and reliable.

Durable Stainless Steel Build: Resists corrosion and mechanical damage, making the tool suitable for long-term use in busy medical testing labs.

Easy Alignment & Adjustment: The marked centre line simplifies precise positioning during tests, while the weight adjustment hole allows customization for unique testing scenarios.


Application


The ZLT-P12 Cylinder Test Tool Probe is tailored for industries focused on medical device safety. Key applications include:

Medical Device Manufacturers: Testing equipment such as hospital beds, patient transfer lifts, surgical tables, and diagnostic machines to ensure moving parts (e.g., bed rails, armrests) do not pose entrapment risks to patients or staff.

Certification Bodies (e.g., TÜV, UL): Conducting third-party entrapment testing for medical devices seeking compliance with IEC 60601-2-52—a mandatory requirement for entering global markets.

Hospital Safety Departments: Auditing existing medical equipment to verify ongoing compliance with safety standards, especially after maintenance or repairs that may alter device dimensions.

R&D Teams: Developing new medical devices, as the ZLT-P12 provides a standardized way to assess how design changes (e.g., adjusted gaps, modified moving parts) impact entrapment risk.


FAQ


Why is the ZLT-P12 made of stainless steel?

Stainless steel is chosen for its durability, corrosion resistance, and consistent density. These properties ensure the tool maintains its weight (3.34 kg±0.05 kg) and structural integrity over time, even in frequent testing or humid lab environments (common in medical facilities).


Can the weight of the ZLT-P12 be adjusted?

Yes. The tool includes a drilling hole specifically for weight adjustment. This allows users to fine-tune the weight if testing requirements deviate slightly from the standard 3.34 kg (e.g., for custom medical device designs). However, adjustments should be made carefully to avoid compromising compliance with IEC 60601-2-52.


What payment methods are accepted for the ZLT-P12?

ZLTJC accepts T/T (Telegraphic Transfer) and D/P (Documents Against Payment) for orders of the ZLT-P12. For large-volume orders, contact the sales team to discuss flexible payment terms.


How long does it take to receive the ZLT-P12 after ordering?

The standard lead time is 10 days from order confirmation. Shipping is from Guangzhou port, and transit times depend on the destination (e.g., 3-5 days for Southeast Asia, 7-14 days for Europe/North America).


 

 

Previous: 
Next: 
We have a professional sales team, extensive suppliers, a deep market presence, and excellent one-stop services.

QUICK LINKS

PRODUCTS CATEGORY

CONTACT US

Phone:+86-18011959092
                +86-13802755618
Tel:+86-20-81600059
         +86-20-81600135
Email: oxq@electricaltest.com.cn
               zlt@electricaltest.com.cn
Add:166-8 Longxi Middle Road, Liwan District, Guangzhou, China
Leave a Message
Contact Us
​Copyright © 2024 Guangzhou Zhilitong Electromechanical Co., Ltd. All rights reserved. | Sitemap | Privacy Policy | Supported by leadong.com